FIRE DIVISION
Telephone (732) 721-5600, Ext. 2420 • Fax (732) 607-4832


The Fire Division is staffed with one Subcode Official and one inspector on a full time basis. We are here to answer your questions during normal business hours. Below are some frequently needed requirements when doing work on your home.

REHAB CODE SMOKE DETECTOR/CO REQUIREMENTS

5:23-6.6(e)9.

Alterations - the rearrangement of any space by the construction of walls or partitions or by a change in ceiling height, the addition or elimination of any door or window, the extension or rearrangement of any system , the installation of any additional equipment or fixtures and any work which reduces the load bearing capacity of or which imposes additional loads on a primary structural component.

A hardwired SD shall be installed within each new bedroom, and a second hardwired SD shall be installed in the vicinity of the bedroom. A UL approved CO detector shall be installed in the vicinity of the bedrooms.

 

 

5:23-6.32(f)1.

Additions - an increase in the footprint area of a building or an increase in the average height of the highest roof surface, or the number of stories in a building.

Hardwired interconnected SD shall be installed on every level, outside each bedroom, and within each bedroom, including the existing portion of the house. A UL approved CO detector shall be installed in the vicinity of the bedrooms.

5:23-6.5(f)

Renovations -removal or replacement or covering of existing interior or exterior trim, finish, doors, windows, or other materials with new materials that serve the same purpose and do not change the configuration of the space.

A SD shall be installed in the vicinity of the bedrooms on every level, and located on or near the ceiling.  Battery operated units shall be permitted. A UL approved CO detector shall be installed in the vicinity of the bedrooms.

5:23-6.27(A) & NJ-IRC 2000-R317.1

Reconstruction - any project where the extent and nature of the work is such that the work area cannot be occupied while the work is in progress and where a new certificate of occupancy is required before re-occupancy. Reconstruction may include repair, renovation, alteration or any combination of the thereof.

Hardwired interconnected SD shall be installed on every level, outside each bedroom, and within each bedroom, including the existing portion of the house. A UL approved CO detector shall be installed in the vicinity of the bedrooms.

Egress Windows

When an addition in constructed all bedrooms within the addition must have at least one window meeting the egress requirements. The first floor must have one window per bedroom that is 3'0" X 4'0" and minimum net clear opening of 24" high and 20" wide. the second floor must have one window per bedroom that is 3'0" X 4'6" with minimum net clear opening of 24" high and 20" wide. In both instances the maximum sash height is 44" from finish floor.

Fire resistance ratings

On exterior walls within 3' of a property line these walls must be fire-rated and have no windows or doors. This means that you will be required to install exterior grade fire rated type X sheetrock to both the outside and inside of that exterior wall.

On garages or additions above garages, ceilings must have 2 layers of 5/8" fire rated sheetrock and one layer of 5/8" fire rated sheetrock on the wall. garage doors are required to be 1 3/4" solid core door with no windows.